International Standard
ISO 22066:2020
Water quality — Determination of total cyanide — Method using segmented flow injection, in-line ultraviolet digestion analysis by gas diffusion and amperometric detection
Reference number
ISO 22066:2020
Версия 1
2020-09
International Standard
Предпросмотр
p
ISO 22066:2020
72488
недоступно на русском языке
Опубликовано (Версия 1, 2020)

ISO 22066:2020

ISO 22066:2020
72488
Формат
Язык
CHF 96
Пересчитать швейцарские франки (CHF) в ваша валюта

Тезис

This document specifies operationally defined methods for the determination of total cyanide in various types of water such as drinking water, ground water, surface water, wastewaters, metallurgical processing tailings reclaim solution, heap leach barren solution, mill slurry tailings filtrate and leaching solutions, with cyanide concentrations from 5 µg/l to 2 000 mg/l expressed as cyanide ions in the undiluted sample. The range of application can be extended by reducing the sensitivity (Figure A.1.).

NOTE ISO 2080:2008, 3.105, defines free cyanide. The concentration of total cyanide as defined in ISO 2080:2008, 3.191 includes free cyanide, cyanide complexed with metals in solution as cyanide anion, but not necessarily all of the metal cyanide complexes present as determined by a specified analytical method.

In this method, six suitable mass concentration ranges from 5 µg/l to 50 µg/l, from 50 µg/l to 500 µg/l, from 0,5 mg/l to 5 mg/l, from 5 mg/l to 50 mg/l, from 50 mg/l to 500 mg/l and from 500 mg/l to 2 000 mg/l are described.

Общая информация

  •  : Опубликовано
     : 2020-09
    : Опубликование международного стандарта [60.60]
  •  : 1
  • ISO/TC 147/SC 2
    13.060.50 
  • RSS обновления

Жизненный цикл

Появились вопросы?

Ознакомьтесь с FAQ

Работа с клиентами
+41 22 749 08 88

Часы работы:
Понедельник – пятница: 09:00-12:00, 14:00-17:00 (UTC+1)